Appliances & electrical

Electrical and lighting supply

The material an installation actually consumes — sized against the load and the run, not against habit.

What this category covers

Wires & cables

House wiring in standard sizes, flexible cable, armoured cable, coaxial, network and speaker cable.

Conduits, boxes & accessories

PVC and metal conduit, bends, junction boxes, back boxes, trunking, glands and saddles.

Switches & sockets

Modular plates and modules, industrial sockets, weatherproof fittings, regulators and dimmers.

Protection & distribution

MCBs, RCCBs, isolators, distribution boards, changeover switches, fuses and earthing material.

Lighting

LED battens, panels, downlights, floods, street and yard lighting, decorative fittings, drivers and lamps.

Fans & ventilation

Ceiling, wall, exhaust and pedestal fans. Ventilation units and their mounting hardware.

Why this sits with security and automation

Every camera, gate motor, access reader and network point needs the same material as a light fitting — cable, conduit, a box, a breaker and an earth. An installation quoted without its electrical material is not a complete quotation.

  • Cable size follows the load and the run length, not habit. A long run at the same size loses voltage, and the symptom looks like a faulty device.
  • Protection has to match the circuit. An MCB rated above the cable protects nothing.
  • Earthing is not optional on metal enclosures, gates, shutters or anything outdoors.
  • Weatherproof means rated, not covered. Goa's monsoon finds the difference within one season.
Where a licensed electrician is required, we arrange one. Supply of material is not the same as certification of an installation, and the two are quoted separately.

Sizing a cable is not a preference

What decides itWhy
Load in ampsThe current the circuit will actually carry, not the appliance rating alone
Run lengthLong runs lose voltage. The device underperforms and the fault looks like the device
Installation methodCable in conduit, buried or bunched with others carries less than cable in free air
Ambient temperatureA hot roof space or plant room derates the cable
Protection ratingAn MCB rated above the cable protects nothing
Undersized cable is the fault that hides. It does not trip, it does not fail immediately — it runs warm, loses voltage and shortens the life of whatever is on the end of it.

What coastal installations need

  • Weatherproof means rated, not covered. An IP rating is a specification. A box with a lid over it is not.
  • Glands and entries are where water gets in, not through the enclosure. Correct glands, entries from below, and drip loops on every cable.
  • Earthing is not optional on metal enclosures, gates, shutters, railings or anything outdoors. In salt air, a poor earth becomes no earth.
  • Stainless or galvanised fixings outside. Plain steel screws in a weatherproof box defeat the box within two seasons.
  • RCD protection on outdoor and wet-area circuits is the difference between a nuisance trip and an incident.
Supply is not certification. We supply the material and install where the work permits it. Where a licensed electrician is required, one is arranged — and the two are quoted separately so it is clear which you are buying.

Send this requirement

Send the items, ratings and quantities you need. We reply with what can be supplied and on what terms.

Supply, installation and service scope is confirmed in writing before work is agreed.